Answer: When the minimum cell voltage of the battery pack is lower than the single cell over-discharge protection voltage and the duration reaches the single cell over-discharge protection delay, the system enters the over-discharge protection state and turns off the discharge MOS. after the over-discharge protection occurs, charging the battery pack can release the over-discharge protection state.